Product Testing Control Technology

         Accurately test each graphite electrode and nipple by y using advanced instrument , including the indices of Weight , Length , Diameter , Density , Specific Resistance , Nipple socket inside diameter , outside diameter , taper and so on . We guarantee the qualified rate of the sold product should be 100%.

Moment For Reference For Connecting Nipples And Electrodes

 

Diameter of Electrode
Moment
 Diameter of Electrode
 Moment
inch
mm
N.m
inch
mm
N.m
8
200
200∽260
14
350
900∽1050
9
225
300∽340
16
400
1000∽1250
10
250
400∽450
18
450
1350∽1600
12
300
550∽720
20
500
1700∽2000

 

Precautions For Using Graphite Electrodes

1 . Please refer to current load and density when make a choice of electrode size.

 2 . Rain , snow and water should be kept away during the transportation and storage of electrode and pre-dry be before use.

 3 . In the process of loading , unloading and transportation , careful handling and special hanger are appreciated in case the damage of thread.

 4 . Compressed air should be used to clear the dust from thread of electrode before nipple and electrode be connected , and make sure that nipple and electrode are properly twisted.

 5 . If iron nipple are used in hoisting the electrode , to make sure that thread of iron nipple are not deformed , in order to avoid the damage of thread of electrode.

 6 . When the electrodes are connected the terminal surface between the electrodes should be integrated closely for certain span with moment spanner.

 7 . During the operation , the elevator of arc furnace should be stable , so that the situation of electrode joints be loosened or dislocated can be avoided.

 8 . The electrode clasper must be within the safety line during the operation.

 9 . To prevent breakage of electrode from scrap cave - ins , the electrode should be up or down according to the melting condition and push the UN-melted waste steel to the furnace pond.

 10 . To have a good effects of dislocation protection , graphite pin and plug are available in our company , and it s convenient for use.

 11 . Before the use of anti-oxidation electrode , to make sure a good connection , the material that separated from the socket should be cleared away.

 

Technology